Projects

 

  • Detailed Design and Supply of the Waveguide Components for the RF Distribution Chains for the RFQ and DTL of the ESS-ERIC Accelerator (Lund, Sweden).Flexible waveguide sections

    Detailed Design and Supply of the Waveguide Components for the RF Distribution Chains for the RFQ and DTL of the ESS-ERIC Accelerator (Lund, Sweden).Flexible waveguide sections

    • Guia Flexible
    • 01
    / 01
    AWGE Passive Devices features:
    • From 352 MHz (VHF) to 40 GHz (Ka band)
    • Low loss special waveguides (up to 3MW)
    • Flexible & rigid
    • Made in: Aluminum, stainless steel, copper,
    • etc.
    • Plated in silver, copper, gold, etc.
    • Straight waveguides
    • Flexible waveguides
    • Elbows, couplers, magic “T” …
    • Phase shifters
  • Design, manufacture and supply of a test cryostat for HARMONI preoptics. IAC (Astrophysical Institute of Canary Islands)

    Design, manufacture and supply of a test cryostat for HARMONI preoptics. IAC (Astrophysical Institute of Canary Islands)

  • Detailed Design and Supply of the Waveguide Components for the RF Distribution Chains for the RFQ and DTL of the ESS-ERIC Accelerator (Lund, Sweden). “Special” waveguide sections

    Detailed Design and Supply of the Waveguide Components for the RF Distribution Chains for the RFQ and DTL of the ESS-ERIC Accelerator (Lund, Sweden). “Special” waveguide sections

  • Design, Assembly and Test of intermediate frecquency signal conditioners and RF signal conditioners & different filter banks range 2-18 GHz & High Power Callibrator System range 0,5-18 GHz. Indra

    Design, Assembly and Test of intermediate frecquency signal conditioners and RF signal conditioners & different filter banks range 2-18 GHz & High Power Callibrator System range 0,5-18 GHz. Indra

  • Supply of Vacuum Flanges for the BPM Feedthroughs on the IFMIF/EVEDA Cryomodule. F4E

    Supply of Vacuum Flanges for the BPM Feedthroughs on the IFMIF/EVEDA Cryomodule. F4E

  • Cryostats and cryogenic manipulators (up to 5 axes)

    Cryostats and cryogenic manipulators (up to 5 axes)

    • Criogenia
    • 01
    / 01
    AWGE Cryostat features:
    • Wide Tª range: 4K (-269 °C) to 600ªC
    • Low consumption
    • High stability
    • Low-cost maintenance (20kh)
    • Cooling time up to 2 hours
    • Ultra-light Cryostats (2kg)
  • Detailed design, Technical Support and Manufacture of Proton Beam Window Seal Mock-Up. ESS Lund

    Detailed design, Technical Support and Manufacture of Proton Beam Window Seal Mock-Up. ESS Lund

  • Study, Fabrication and Assembly of a Radial Oscillating Collimator (ROC) for the Instrument XTREMED

    Study, Fabrication and Assembly of a Radial Oscillating Collimator (ROC) for the Instrument XTREMED

  • Mechanical Engineering_Monolith Vessel

    Mechanical Engineering_Monolith Vessel

  • Engineering of Shielding

    Engineering of Shielding

    AWGE Engineering of Shielding: Structural Design Thermal and vibrational calculations 3D Modeling Manufacturing design Complex Mechanical design Material & Test Mobile Structure; easy to level
  • Isolated Vacuum Flanges

    Isolated Vacuum Flanges

  • Website optimized for all browsers and devices. If you browse with Internet Explorer version 9 or higher is required.
  • Layout: Eduardo Garcia & Sergio Robles | Web Design: ©Coinfes. | Total or partial reproduction of the website content is prohibited.
Press enter to search
Press enter to search